TN-S vs TN-C-S vs TT vs IT — Earthing System Comparison Poster
Free download · A4 portrait
Understanding earthing systems is fundamental to electrical design, yet many engineers struggle to visualise the differences between TN-S, TN-C-S, TT, and IT configurations. This A4 portrait poster presents each of the four earthing systems as a clear single-line diagram showing the source transformer, distribution network, and installation earthing arrangement. Colour-coded conductors (brown for line, blue for neutral, green-yellow for earth, and dashed for PEN) make it easy to trace the fault current return path for each system. Below each diagram, a characteristics panel lists the key properties: earth fault loop impedance behaviour, touch voltage risk, RCD requirements, and the specific IEC 60364-1 clause that defines the system. A comparison table at the bottom summarises mandatory protection devices for each system — TN-S and TN-C-S rely on overcurrent protection with RCDs recommended, TT systems require RCD protection as the primary earth fault device, and IT systems need insulation monitoring devices (IMDs) with alarm-on-first-fault capability. The poster also covers where each system is typically used: TN-S in new UK and Australian installations, TN-C-S (PME) for UK supply networks, TT in rural areas and developing countries, and IT in hospitals, mines, and process plants where continuity of supply is critical. Essential for electrical engineering students, apprentices learning system design, and experienced engineers who need a quick visual reference when specifying protection schemes.
What's Included
How to Print
- ●Print on A3 (297 × 420mm) or tabloid (11 × 17")
- ●Color printing required for comparison highlights
- ●Use a professional print shop for best results
- ●Frame or laminate for long-term office display
Try the Interactive Calculator
Need precise calculations beyond quick reference? Try our free online calculator with full clause references and professional report output.
Open CalculatorRelated Downloads
Earthing System
Free printable earthing system testing checklist. 20-item checklist covering electrode installation, resistance testing, bonding, and fault verification per AS/NZS 3000, BS 7671, IEEE 80, NEC 250.
IP/IK Rating Chart
Free printable IP and IK rating reference chart poster. Full IP matrix (IP00–IP69K), IK impact scale (IK01–IK10 with joules), common applications, and minimum ratings per AS/NZS 3000 and BS 7671.
Cable Ratings Poster
Free printable A3 wall poster comparing cable current ratings across AS/NZS 3008, BS 7671, IEC 60364, and NEC side-by-side. Pin in your design office.
Frequently Asked Questions
Which earthing system is used in my country?
TN-S and TN-C-S (PME) are standard in the UK, Australia, and most of Europe. TT is common in France, rural areas, and developing countries. IT is used in hospitals, mines, and process industries globally. Check your local supply authority for the system in your area.
What paper should I print this on?
Print on A4 portrait in colour — the colour-coded conductors are essential for understanding fault paths. Laminate and post in training rooms and design offices.
What standard does this reference?
Earthing system definitions per IEC 60364-1, with protection requirements from IEC 60364-4-41. The diagrams also align with BS 7671:2018+A2 and AS/NZS 3000:2018 terminology.
How often is this updated?
Earthing system definitions are stable across editions. Updated if IEC 60364-1 introduces changes to system classifications or protection requirements.