Lighting & Small Power Schedule Template (Excel)
Free download · Excel (.xlsx)
Plan lighting and small power circuits with this Excel template. Captures circuit reference, area/room, luminaire type and wattage, quantity, total load, control type (switch/PIR/DALI/timer), emergency classification, phase assignment, socket outlet details, total circuit load, cable type and size, protection device rating, and switchboard reference. Essential for detailed design of commercial and industrial lighting installations.
What's Included
How to Print
- ●Open in Microsoft Excel 2016+, Google Sheets, or LibreOffice Calc
- ●Add your company logo and project details to the header
- ●Copy data rows to add more circuits or equipment
- ●Print on A4 or A3 landscape for site records
- ●Keep completed records for design verification and audit trail
Try the Interactive Calculator
Need precise calculations beyond quick reference? Try our free online calculator with full clause references and professional report output.
Open CalculatorRelated Downloads
Load Schedule
Download a free electrical load schedule template Excel per IEC 60364 and NEC Art 220. Columns for equipment tag, rated power, phases, demand factor, feeder ref, and annual energy. No signup required.
Switchboard Schedule
Free switchboard schedule template Excel download. Pre-formatted for circuit details, protection devices, cable sizes. Professional engineering layout.
Max Demand Record
Download a free maximum demand assessment record template Excel per AS/NZS 3000, BS 7671, and NEC Art 220. Columns for load groups, demand factors, diversity, phase assignment, and transformer sizing. No signup required.
Frequently Asked Questions
What is a lighting and small power schedule?
A lighting and small power schedule lists every lighting and socket outlet circuit in an installation, documenting luminaire types, loads, controls, and circuit details. It is used for detailed design, load balancing across phases, and compliance with IEC 60364 and NEC requirements.
What should a lighting schedule include?
Key fields include circuit reference, area/room served, luminaire type and wattage, quantity, total load, control method (switch/PIR/DALI/timer), emergency classification, phase assignment, socket outlet quantity and rating, cable type and size, and protection device rating.
How do you calculate lighting load for circuit design?
Sum the wattage of all luminaires on the circuit including control gear losses (typically 10–15% for LED drivers). Add socket outlet load allowance — BS 7671 uses 100W per socket for design purposes. The total determines cable size and protection device rating. Balance loads across phases to within 10%.